Measuring the Boltzmann constant by mid-infrared laser spectroscopy of ammonia - Université de Lille Accéder directement au contenu
Article Dans Une Revue Metrologia Année : 2015

Measuring the Boltzmann constant by mid-infrared laser spectroscopy of ammonia

S Mejri
  • Fonction : Auteur
Papa Lat Tabara Sow
  • Fonction : Auteur
  • PersonId : 917844
O Kozlova
  • Fonction : Auteur
  • PersonId : 1142024
  • IdRef : 165783478
C Ayari
  • Fonction : Auteur
Sean K. Tokunaga
  • Fonction : Auteur
  • PersonId : 945554
C Chardonnet
  • Fonction : Auteur
Stéphan Briaudeau
  • Fonction : Auteur
  • PersonId : 1129855
B Darquié
  • Fonction : Auteur
C Daussy

Résumé

We report on our ongoing effort to measure the Boltzmann constant, k B , using the Doppler broadening technique on ammonia. This paper presents some of the improvements made to the mid-infrared spectrometer including the use of a phase-stabilized quantum cascade laser, a lineshape analysis based on a refined physical model and an improved fitting program 2 increasing the confidence in our estimates of the relevant molecular parameters, and a first evaluation of the saturation parameter and its impact on the measurement of k B. A summary of the systematic effects contributing to the measurement is given and the optimal experimental conditions for mitigating those effects in order to reach a competitive measurement of k B at a part per million accuracy level are outlined.
Fichier principal
Vignette du fichier
Mejri Boltzmann Metrologia ArXiv.pdf (755.21 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-01159864 , version 1 (03-06-2015)

Identifiants

Citer

S Mejri, Papa Lat Tabara Sow, O Kozlova, C Ayari, Sean K. Tokunaga, et al.. Measuring the Boltzmann constant by mid-infrared laser spectroscopy of ammonia. Metrologia, 2015, 52, pp.S314-S323. ⟨10.1088/0026-1394/52/5/S314⟩. ⟨hal-01159864⟩
153 Consultations
106 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More