, l: 1g/ and 500mg/l: 1g/l) are the used reagent fractions of FeSO4, vol.7, pp.2-2

M. Alaee and R. J. Wenning, The significance of brominated flame retardants in the environment: current understanding, issues and challenges, Chemosphere, vol.46, pp.579-582, 2002.

J. M. Allwood, N. Bocken, S. E. Laursen, and R. C. Malvido, Well Dressed? The Present & Future Sustainability of Clothing & Textiles in the UK, 2006.

U. Arena, M. L. Mastellone, and F. Perugini, The environmental performance of alternative solid waste management options: a life cycle assessment study, Chem. Eng. J, vol.96, pp.207-222, 2003.

, Standard Test Method for Determining Flammability Characteristics of Plastics and Other Solid Materials Using Microscale Combustion Calorimetry, ASTM, 2007.

A. Bacaloni, C. Cavaliere, P. Foglia, M. Nazzari, R. Samperi et al., Liquid chromatography/tandem mass spectrometry determination of organophosphorus flame retardants and plasticizers in drinking and surface waters, Rapid Commun. Mass Spectrom, vol.21, pp.1123-1130, 2007.

M. I. Badawy, M. Y. Ghaly, and T. A. Gad-allah, Advanced oxidation processes for the removal of organophosphorus pesticides from wastewater, Desalination, vol.194, pp.166-175, 2006.

P. Bajaj, Heat and flame protection, Handb. Tech. Text, pp.223-263, 2000.

P. Basu, Biomass gasification, pyrolysis and torrefaction: practical design and theory, 2013.

G. Baydar, N. Ciliz, and A. Mammadov, Life cycle assessment of cotton textile products in Turkey, Resour. Conserv. Recycl, vol.104, pp.213-223, 2015.

A. Beton, D. Dias, L. Farrant, T. Gibon, Y. Le-guern et al., Environmental improvement potential of textiles (IMPRO-textiles), JRC Sci. Policy Rep. Eur. Comm. JRC-IPTS Bio Intell. Serv. ENSAIT Ecole Natl. Supér. Arts Ind. Text. Sevilla Ftp Jrc EsEURdocJRC85895 Pdf Accessed, vol.20, 2014.

S. Bischof-vuku?i? and A. Katovi?, Formaldehyde Free Binding System for Flame Retardant Finishing of Cotton Fabrics, FIBRES Text. East. Eur, vol.20, p.90, 2012.

A. A. Burbano, D. D. Dionysiou, M. T. Suidan, and T. L. Richardson, Oxidation kinetics and effect of pH on the degradation of MTBE with Fenton reagent, Water Res, vol.39, pp.107-118, 2005.

I. Casero, D. Sicilia, S. Rubio, and D. Pérez-bendito, Chemical degradation of aromatic amines by Fenton's reagent, Water Res, vol.31, 1985.

E. Cefic, Recycling and disposal End of life of products containing flame retardants, 2006.

M. W. Clark and B. A. Andrewes, Ester crosslinks: A route to high performance nonformaldehyde finishing of cotton, Text. Chem. Color, vol.21, pp.13-17, 1989.

, Centre of Fire Statistics of CTIF, World Fire Statistics, issue.10, 2006.

F. J. Cui, Y. Li, Z. H. Xu, H. Y. Xu, K. Sun et al., Optimization of the medium composition for production of mycelial biomass and exo-polymer by Grifola frondosa GF9801 using response surface methodology, Bioresour. Technol, vol.97, pp.1209-1216, 2006.

M. Curti, Solids and gas hydrodynamic characteristics in square-based spouted beds for thermal applications, 2015.

M. A. Curran, LIFE CYCLE ASSESSMENT: PRINCIPLES AND PRACTICE, 2006.

L. Dahllöf, Methodological issues in the LCA procedure for the textile sector, 2004.

. Defra, Fire Retardant Technologies: safe products with optimised environmental hazard and risk performance. Review of Alternative Fire Retardant Technologies, 2010.

, Frequently Asked Questions, EFRA, 2007.

O. Egyed and J. Simon, Investigations on the flame-retardation of cellulosic fibrous materials: I. Thermal analysis, J. Therm. Anal. Calorim, vol.16, pp.307-320, 1979.

A. El-shafei, M. Elshemy, and A. Abou-okeil, Eco-friendly finishing agent for cotton fabrics to improve flame retardant and antibacterial properties, Carbohydr. Polym, vol.118, pp.83-90, 2015.

, Life Cycle and Risk Assessment of Environment-Compatible Flame Retardants (Prototypical Case Study): ENFIRO (No. KP7-226563), ENFIRO, 2009.

S. Esplugas, J. Gimenez, S. Contreras, E. Pascual, and M. Rodr??guezrodr??guez, Comparison of different advanced oxidation processes for phenol degradation, Water Res, vol.36, pp.1034-1042, 2002.

F. Ferrero and M. Periolatto, Glycerol in comparison with ethanol in alcohol-assisted dyeing, J. Clean. Prod, vol.33, pp.127-131, 2012.

G. Finnveden, J. Johansson, and P. Lind, Life cycle assessment of energy from solid waste-part 1: general methodology and results, J. Clean. Prod, vol.13, pp.213-229, 2005.

J. F. Fowler, S. M. Skinner, and D. V. Belsito, Allergic contact dermatitis from formaldehyde resins in permanent press clothing: an underdiagnosed cause of generalized dermatitis, J. Am. Acad. Dermatol, vol.27, pp.962-968, 1992.

T. Fruergaard and T. Astrup, Optimal utilization of waste-to-energy in an LCA perspective, Waste Manag, vol.31, pp.572-582, 2011.

P. Gerike, The biodegradability testing of poorly water soluble compounds, Chemosphere, vol.13, pp.169-190, 1984.

W. H. Glaze, J. Kang, and D. H. Chapin, The chemistry of water treatment processes involving ozone, hydrogen peroxide and ultraviolet radiation, 1987.

S. Harimurti, B. K. Dutta, I. F. Ariff, S. Chakrabarti, and D. Vione, Degradation of monoethanolamine in aqueous solution by Fenton's reagent with biological posttreatment, Water. Air. Soil Pollut, vol.211, pp.273-286, 2010.

B. G. Hermann, C. Kroeze, and W. Jawjit, Assessing environmental performance by combining life cycle assessment, multi-criteria analysis and environmental performance indicators, J. Clean. Prod, vol.15, pp.1787-1796, 2007.

A. R. Horrocks, Developments in flame retardants for heat and fire resistant textiles-the role of char formation and intumescence, Polym. Degrad. Stab, vol.54, pp.143-154, 1996.

A. R. Horrocks and D. Price, Fire retardant materials, 2001.

, Worldwide flame retardants market to reach 2.8 million tonnes in 2018, Addit. Polym, p.11, 2015.

, ISO14040 -Environmental Management -Life Cycle Assessment Principles and Framework, ISO14040, 2006.

, ISO14044 -Environmental Management -Life Cycle Assessment -Requirements and Guidelines, ISO14044, 2006.

E. Ison and A. Miller, The use of LCA to introduce life-cycle thinking into decision-making for the purchase of medical devices in the NHS, J. Environ. Assess. Policy Manag, vol.2, pp.453-476, 2000.

P. Jain and N. Vigneshwaran, Effect of Fenton's pretreatment on cotton cellulosic substrates to enhance its enzymatic hydrolysis response, Bioresour. Technol, vol.103, pp.219-226, 2012.

W. Jawjit, P. Pavasant, and C. Kroeze, Evaluating environmental performance of concentrated latex production in Thailand, J. Clean. Prod, vol.98, pp.84-91, 2015.

W. John, Flame retardants, The Case for Policy Change, 2013.

N. Jonkers, H. Krop, H. Van-ewijk, and P. E. Leonards, Life cycle assessment of flame retardants in an electronics application, Int. J. Life Cycle Assess, vol.21, pp.146-161, 2016.

J. , Healthy Building Network in conjunction with Health Care Without Harm's research collaborative, 2007.

E. Kalliala and P. Talvenmaa, Environmental profile of textile wet processing in Finland, J. Clean. Prod, vol.8, pp.143-154, 2000.

N. Kang, D. S. Lee, and J. Yoon, Kinetic modeling of Fenton oxidation of phenol and monochlorophenols, Chemosphere, vol.47, pp.915-924, 2002.

J. W. Kim, T. Isobe, K. H. Chang, A. Amano, R. H. Maneja et al., Levels of triaryl/alkyl phosphate in human tissue from eastern Ontrario, Bull Env. Contam Toxicol, vol.37, pp.41-46, 1986.

E. Koç and E. Kaplan, An investigation on energy consumption in yarn production with special reference to ring spinning, Fibres Text. East. Eur, pp.18-24, 2007.

K. Kooistra, A. Termorshuizen, and R. Pyburn, The sustainability of cotton, Consequences Man Environ. Rep, vol.223, 2006.

A. Kumar, D. D. Jones, and M. A. Hanna, Thermochemical biomass gasification: a review of the current status of the technology, vol.2, pp.556-581, 2009.

. Larsen, , 2000.

R. E. Lyon and R. N. Walters, Pyrolysis combustion flow calorimetry, J. Anal. Appl. Pyrolysis, vol.71, pp.27-46, 2004.

M. K. Mann and P. L. Spath, Life cycle assessment of a biomass gasification combined-cycle power system, 1997.

A. Marklund, B. Andersson, and P. Haglund, Organophosphorus flame retardants and plasticizers in Swedish sewage treatment plants, Environ. Sci. Technol, vol.39, pp.7423-7429, 2005.

A. Mcpherson, B. Thorpe, and A. Blake, Brominated flame retardants in dust on computers: the case for safer chemicals and better computer design. Clean Prot, Action P, p.43, 2004.

N. Meksi, M. B. Ticha, M. Kechida, and M. F. Mhenni, Using of ecofriendly ?-hydroxycarbonyls as reducing agents to replace sodium dithionite in indigo dyeing processes, J. Clean. Prod, vol.24, pp.149-158, 2012.

J. Meyer and K. Bester, Organophosphate flame retardants and plasticisers in wastewater treatment plants, J. Environ. Monit, vol.6, pp.599-605, 2004.

M. Mohsin, S. W. Ahmad, A. Khatri, and B. Zahid, Performance enhancement of fire retardant finish with environment friendly bio cross-linker for cotton, J. Clean. Prod, vol.51, pp.191-195, 2013.

S. S. Muthu, Assessing the environmental impact of textiles and the clothing supply chain, 2014.

S. Nazaré and R. S. ;--blackburn, 14 -Environmentally friendly flame-retardant textiles A2, Sustainable Textiles, pp.339-368, 2009.

. Nf and . Iso-, Tensile properties of fabric-part-1, determination of maximum force and elongation using strip method, 2013.

. Nf-g, Methods for assessing the burning behaviour of textiles Classification of damaged area, pp.7-113, 1972.

R. Nielsen and A. Schmidt, Changing consumer behaviour towards increased prevention of textile waste. FORCE Technology, 2014.

A. Pandey, T. Bhaskar, M. Stöcker, and R. Sukumaran, Recent advances in thermochemical conversion of biomass, 2015.

R. Paul, Functional finishes for textiles: Improving comfort, performance and protection, 2014.

A. Petra, S. Margaret, and H. Stripple, Fire safety of upholstered furniture, SP, vol.22, 2003.

T. Ramachandran, K. Vellingiri, and M. S. Kannan, A Comparative Study of Durable Flame Retardant Finish on Cotton Fabrics, J. Inst. Eng. India, vol.85, pp.29-32, 2005.

J. H. Ramirez, F. M. Duarte, F. G. Martins, C. A. Costa, and L. M. Madeira, Modelling of the synthetic dye Orange II degradation using Fenton's reagent: From batch to continuous reactor operation, Chem. Eng. J, vol.148, pp.394-404, 2009.

M. Rättö, A. Ritschkoff, and L. Viikari, The effect of oxidative pretreatment on cellulose degradation by Poria placenta and Trichoderma reesei cellulases, Appl. Microbiol. Biotechnol, vol.48, pp.53-57, 1997.

S. Ravichandran, R. M. Bouldin, J. Kumar, and R. Nagarajan, A renewable waste material for the synthesis of a novel non-halogenated flame retardant polymer, J. Clean. Prod, vol.19, pp.454-458, 2011.

. Redfr, Gnosys Summary Work Package D -Life Cycle Assessment, RedFR Final Consortium Meeting, 2011.

R. Rodil, J. B. Quintana, E. Concha-graña, P. López-mahía, S. Muniategui-lorenzo et al., Emerging pollutants in sewage, surface and drinking water in Galicia, Chemosphere, vol.86, pp.1040-1049, 2012.

W. J. Rogan, B. C. Gladen, J. D. Mckinney, N. Carreras, P. Hardy et al., Polychlorinated biphenyls (PCBs) and dichlorodiphenyl dichloroethene (DDE) in human milk: effects of maternal factors and previous lactation, Am. J. Public Health, vol.76, pp.172-177, 1986.

S. H. Safe, Polychlorinated biphenyls (PCBs): environmental impact, biochemical and toxic responses, and implications for risk assessment, Crit. Rev. Toxicol, vol.24, pp.87-149, 1994.

I. Saito, A. Onuki, and H. Seto, Indoor organophosphate and polybrominated flame retardants in Tokyo, Indoor Air, vol.17, pp.28-36, 2007.

W. D. Schindler and P. J. Hauser, Chemical finishing of textiles, 2004.

M. Simonson, Fire-LCA model: TV case study, 2000.

M. Simonson, P. Andersson, P. Blomqvist, and H. Stripple, Environmental assessment of fires in products using the Fire-LCA model, Fire Saf. Sci, vol.8, pp.1071-1082, 2005.

H. M. Stapleton, S. Klosterhaus, S. Eagle, J. Fuh, J. D. Meeker et al., Detection of organophosphate flame retardants in furniture foam and US house dust, Environ. Sci. Technol, vol.43, pp.7490-7495, 2009.

A. M. Sundkvist, U. Olofsson, and P. Haglund, Organophosphorus flame retardants and plasticizers in marine and fresh water biota and in human milk, J. Environ. Monit, vol.12, pp.943-951, 2010.

Z. Tovarna and T. , Eco-Friendly Durable Press Finishing of Textile Interlinings, 2002.

L. Turunen and H. Van-der-werf, Life cycle analysis of hemp textile yarn, INRA Fr. Natl. Inst. Agron. Res. Fr, 2006.

F. Uddin, Recent development in combining flame-retardant and easy-care finishing for cotton, Cellul. Chem Technol, vol.47, pp.469-477, 2013.

I. Van-der-veen and J. De-boer, Phosphorus flame retardants: properties, production, environmental occurrence, toxicity and analysis, Chemosphere, vol.88, pp.1119-1153, 2012.

L. Vecchione, M. Moneti, E. Bocci, A. D. Carlo, and P. Foscolo, Steam Gasification of Pine Wood in a Fluidized Bed Reactor: Model Development and Validation at Different Operative Conditions, 21st European Biomass Conference and Exhibition, pp.841-848, 2013.

S. B. Vuku?i?, S. F. Grgac, D. Katovi?, and K. Andrea, Evolved Gas Analysis and Flame Retardant Characterisation of Textiles treated with Organophosphorus based Compounds, The World Congress on CBRN Threat and Terrorism, 2011.

L. Wang, C. L. Weller, D. D. Jones, and M. A. Hanna, Contemporary issues in thermal gasification of biomass and its application to electricity and fuel production, Biomass Bioenergy, vol.32, pp.573-581, 2008.

W. Wang, B. Yu, and C. Zhong, Use of ultrasonic energy in the enzymatic desizing of cotton fabric, J. Clean. Prod, vol.33, pp.179-182, 2012.

. Wargo, Flame Retardants, The Case for Policy Change. Environment and Human Health, 2013.

E. D. Weil and S. V. Levchik, Flame retardants in commercial use or development for textiles, J. Fire Sci, vol.26, pp.243-281, 2008.

I. Who, Monographs on the Evaluation of Carcinogenic Risks to Humans, 2006.

W. Wu and C. Q. Yang, A comparative study of different organophosphorus flame retardant agents for cotton: Part II: The fabric flammability and physical properties, Polym Degrad Stab, vol.92, pp.363-369, 2007.

W. Wu and C. Q. Yang, Comparison of different reactive organophosphorus flame retardant agents for cotton: part I. The bonding of the flame retardant agents to cotton, Polym. Degrad. Stab, vol.91, pp.2541-2548, 2006.

W. Xing, G. Jie, L. Song, S. Hu, X. Lv et al., Flame retardancy and thermal degradation of cotton textiles based on UV-curable flame retardant coatings, Thermochim. Acta, vol.513, pp.75-82, 2011.

M. Xu, Q. Wang, and Y. Hao, Removal of organic carbon from wastepaper pulp effluent by lab-scale solar photo-Fenton process, J. Hazard. Mater, vol.148, pp.103-109, 2007.

I. Yilmaz, H. Akcaoz, and B. Ozkan, An analysis of energy use and input costs for cotton production in Turkey, Renew. Energy, vol.30, pp.145-155, 2005.

P. Zhu, S. Sui, B. Wang, K. Sun, and G. Sun, A study of pyrolysis and pyrolysis products of flame-retardant cotton fabrics by DSC, TGA, and PY-GC-MS, J. Anal. Appl. Pyrolysis, vol.71, pp.645-655, 2004.

, Stephane Giraud, Anne Perwuelz. In-situ degradation of organophosphorus flame retardant on cellulosic fabric using advanced oxidation process: A study on degradation and characterization, Publications References Ø Paper I: Sohail Yasin, Nameshwaree Behary, vol.126, pp.1-8, 2016.

Ø. Paper, I. I. Sohail-yasin, N. Behary, G. Rovero, and V. Kumar, Statistical analysis of use-phase energy consumption of textile products, The International Journal of Life Cycle Assessment, pp.1-13, 2016.

Ø. Paper, I. Sohail-yasin, N. Behary, M. Curti, and G. Rovero, Global Consumption of Flame Retardants and Related Environmental Concerns: A Study on Possible Mechanical Recycling of Flame Retardant Textiles, Fibers, vol.4, pp.1-16, 2016.

Ø. Paper, I. V. Sohail-yasin, M. Curti, G. Rovero, N. Behary et al., An Alternative for the End-of-life Phase of Flame Retardant Textile Products: Degradation of Flame Retardant and Preliminary Settings of Energy Valorization by Gasification, BioResources, vol.12, issue.3, pp.5071-5085

Ø. Paper, V. Sohail-yasin, B. Parag, N. Behary, and R. Giorgio, Optimizing Organophosphorus Fire Resistant Finish for Cotton Fabric Using BoxBehnken Design, International Journal of Environmental Research, vol.10, pp.313-320, 2016.

Ø. Paper, V. I. Sohail-yasin, C. Massimo, B. Nemeshwaree, R. Giorgio et al., Process optimization of eco-friendly flame retardant finish for cotton fabric: A response surface methodology approach, Surface Review and Letters, 2017.

N. Ø-conference-paper-i:-sohail-yasin, A. Behary, J. Perwuelz, G. Guan, and . Chen, Degradation Kinetics of Organophosphorus Flame Retardant from Cotton Fabric, 2nd ICAMEST 2016 International Conference on Advanced Material and Engineering Structural Technology, 2016.

, Anne Perwuelz, Nameshwaree Behary. Case study of life cycle inventory of cotton curtain, Ø Conference Paper II: Sohail Yasin, 2014.

. Ø-conference-paper, N. Iii:-sohail-yasin, S. Behary, A. Giraud, and . Perwuelz, Degradation of phosphorus based flame retardant by IR radiation, 15th AUTEX World Textile Conference, 2015.