Inter-day test–retest reliability and feasibility of isokinetic, isometric, and isotonic measurements to assess quadriceps endurance in people with chronic obstructive pulmonary disease: A multicenter study - Université de Lille Accéder directement au contenu
Article Dans Une Revue Chronic Respiratory Disease Année : 2018

Inter-day test–retest reliability and feasibility of isokinetic, isometric, and isotonic measurements to assess quadriceps endurance in people with chronic obstructive pulmonary disease: A multicenter study

Résumé

The aims were to determine reliability and feasibility of measurements to assess quadriceps endurance in people with chronic obstructive pulmonary disease. Sixty participants (forced expiratory volume in one second (mean ± standard deviation) 55 ± 18% of predicted, age 67 ± 8 years) were tested in an inter-day, test–retest design. Isokinetic, isometric, and isotonic protocols were performed using a computerized dynamometer. Test–retest relative and absolute reliability was determined via intraclass correlation coefficient (ICC), coefficient of variation (CV%), and limits of agreement (LoA%). Isokinetic total work demonstrated very high relative reliability (ICC: [95% confidence interval] = 0.98 [0.94–0.99]) and the best absolute reliability (CV% (LoA%) = 6.5% (18.0%)). Isokinetic fatigue index, isometric, and isotonic measures demonstrated low-to-high relative reliability (ICC = 0.64 [0.46–0.77], 0.88 [0.76–0.94], 0.91 [0.85–0.94]), and measures of absolute reliability (CV% (LoA%)) were 20.3% (56.4%), 14.9% (40.8%), and 15.8% (43.1%). For isokinetic total work and isometric measurements, participants performed better on retest (4.8% and 10.0%, respectively). The feasibility was similar across protocols with an average time consumption of less than 7.5 minutes. In conclusion, isokinetic, isometric, and isotonic measurements of quadriceps endurance were feasible to a similar extent and presented low-to-very high relative reliability. Absolute reliability seems to favor isokinetic total work measurements.
Fichier principal
Vignette du fichier
Articles-RFEQ-publié-CRD-2018.pdf (1.88 Mo) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte

Dates et versions

hal-02530662 , version 1 (03-04-2020)

Licence

Paternité

Identifiants

Citer

Erik Frykholm, Sarah Gephine, Didier Saey, Hieronymus van Hees, Arthur Lemson, et al.. Inter-day test–retest reliability and feasibility of isokinetic, isometric, and isotonic measurements to assess quadriceps endurance in people with chronic obstructive pulmonary disease: A multicenter study. Chronic Respiratory Disease, 2018, 16, pp.1-9. ⟨10.1177/1479973118816497⟩. ⟨hal-02530662⟩

Collections

UNIV-LILLE
11 Consultations
27 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More