Magneto-thermal characterization of bulk forged magnetic steel used in claw pole machine
Résumé
During the operation of Claw Pole (CP) machines, and for some operating loads, the magnetic core temperature can reach 180°C in some hot spots. As a consequence, the core electromagnetic properties may considerably change, impacting the machine performances. In such a case, a deep knowledge of the electromagnetic behavior as a function of the temperature is required. In this work, we present a dedicated study of the CP rotor made of a forged magnetic steel. In fact, the CP magnetic properties heterogeneity and the claw shape made it necessary to extract specific samples that are characterized with a miniaturized Single Sheet Tester (SST). To that end, this work proposes a specific methodology to characterize the electromagnetic properties of the CP rotor material as a function of the temperature in order to better predict the machine electrical performances, especially regarding the iron losses.
Origine | Fichiers produits par l'(les) auteur(s) |
---|