PWM Strategy for the Cancellation of Common-Mode Voltage Generated by Three-Phase Back-to-Back Inverters - Université de Lille
Article Dans Une Revue IEEE Transactions on Power Electronics Année : 2017

PWM Strategy for the Cancellation of Common-Mode Voltage Generated by Three-Phase Back-to-Back Inverters

Résumé

This paper presents a pulse width modulation strategy for the cancellation of common-mode (CM) voltage generated by three-phase back-to-back two-level inverters. This method theoretically provides complete elimination of the CM voltage by synchronizing all the commutations of one converter with commutations of the other one, so that the overall resulting CM voltage does not vary. The degrees of freedom of this strategy are studied and an experimental implementation is carried out on a 15-kW motor drive prototype to validate the method effectiveness. Taking into account deadtime compensation, measurements in time and frequency domains show that the CM voltage is strongly reduced and that more than 15 dB reduction is achieved in a wide frequency range.
Fichier principal
Vignette du fichier
Author_version_postprint.pdf (1.01 Mo) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03832926 , version 1 (28-10-2022)

Identifiants

Citer

Arnaud Videt, Medhi Messaoudi, Nadir Idir, Hocine Boulharts, Heu Vang. PWM Strategy for the Cancellation of Common-Mode Voltage Generated by Three-Phase Back-to-Back Inverters. IEEE Transactions on Power Electronics, 2017, IEEE TRANSACTIONS ON POWER ELECTRONICS, 32 (4), pp.2675-2686. ⟨10.1109/TPEL.2016.2573831⟩. ⟨hal-03832926⟩
33 Consultations
65 Téléchargements

Altmetric

Partager

More